Pulsafeeder L0301400-THY TFE/Hypalon Diaphragm - Size 7 PULSAtron

Pulsafeeder L0301400-THY TFE/Hypalon Diaphragm - Size 7 PULSAtron

2.500-Inch TFE/Hypalon Diaphragm for Size 7 Pump Heads
SKU:L0301400-THY
Model Number: L0301400-THY
$123.400

Genuine Pulsafeeder TFE/Hypalon replacement diaphragm, identified as item 2 in PULSAtron wet-end parts diagrams. Listed for compatible size 7 pump configurations.


WHERE TO BUY?
Overview
Specification
Overview

Pulsafeeder L0301400-THY TFE/Hypalon Pump Diaphragm

The Pulsafeeder L0301400-THY is a replacement diaphragm for compatible size 7 PULSAtron chemical metering pump configurations. Manufacturer parts identification documentation lists this part as the diaphragm used in selected wet ends when the fourth character of the pump model is 7.

Manufacturer Specifications

  • Manufacturer: Pulsafeeder
  • Part Number: L0301400-THY
  • Product Type: Metering Pump Diaphragm
  • Material Designation: TFE / Hypalon
  • Common Material Names: PTFE / CSPE
  • Pump Size Designation: Size 7
  • Parts Diagram Position: Item 2 - Diaphragm
  • Example Listed Wet-End Family: PVT3

Diaphragm Function in a Metering Pump

The diaphragm is a flexible component that separates the pump drive mechanism from the chemical liquid end. Its reciprocating movement changes the volume inside the pump chamber, allowing chemical solution to be drawn in and discharged through the pump check valves.

TFE and Hypalon Construction

The manufacturer describes this replacement as a TFE/Hypalon diaphragm. Material selection is important because the diaphragm must tolerate repeated flexing while remaining suitable for the chemical service conditions specified for the original pump.

Size 7 Compatibility Verification

The official PULSAtron parts guide lists L0301400-THY for size 7 variants of certain wet ends, including PVT3. Confirm the complete pump model and original diaphragm part number before ordering. Size designation alone does not establish compatibility with every PULSAtron model.

Inspection and Replacement

Inspect diaphragms according to the pump maintenance schedule. Signs of damage may include chemical leakage, reduced output or visible deterioration. These symptoms can have other causes, so inspect the full liquid end when troubleshooting.

Safe Maintenance

Disconnect power, isolate the chemical supply, drain and depressurize the liquid end before diaphragm replacement. Follow the manufacturer procedure for assembly and tightening requirements.

Ordering Information

Specify Pulsafeeder L0301400-THY for the TFE/Hypalon replacement diaphragm listed for the original compatible size 7 PULSAtron pump.

Specification